- BAR
- 17
- KPA
- 1700
- VACUUM TO PSIG
- 2

- CHAUVIN ARNOX AEMC CORPORATION LIGHT METER MODEL
- 814

- NO
- T1M816590
- STYLE
- S1,R1
- SUFFIX
- 000/A34/FM

- ADJUSTABLE FREQUENCY DRIVE CAT NO
- 22C-D030N103
- MFD
- IN 2015 ON SEP.29
- FRN
- 7.01

- NO
- 88007104
- FLUID
- NG
- FM-RATED FOR A NON-OPERATIONAL UPSTREAM PRESSURE OF
- 10 PSIG

- HURTZ AND AMP METERS CONSISTING OF
- . 4). MC 0-1000 VOLT GAUGE
- NO
- 0400142

- REXROTH MNR
- R900972654
- FD
- 76020
- INDUSTRIAL HYDRAULIC PROPORTIONAL VALVE SERIAL NO
- 20

- NO
- WPLN4197A
- INPUT
- 100-240 VAC
- AMPS
- 3.0

- 1.) NO
- 209119-17-8
- 1.) N0
- 209119-17-4
- 1) NO
- 209119-17-13

- MICRO MOTION FLOW METER SENSOR
- DEO65S113NU
- METER TYPE
- 4
- METER FACTOR
- 18593

- METER TYPE
- 23
- METER FACTOR
- 08965
- DENS CAL FACTOR
- 09770107072.75

- CERT SPEC
- CS-E/FN-F
- REF NO
- 4826174 A
- ORIGIN
- 2A8329

- B/M
- 15965-286/14MH
- RANGE
- 0-15 IN H20
- MAX WPR
- 100 PSI

- RANGE
- -400 400 IN H2O
- PROCESS LIMITS
- -40 TO 85 DEG C
- FACTORY CAL
- 0-100 IN H2O

- ROSEMOUNT SMART TRANSMITTER MODEL
- 2051CDA22A1AT2B4
- CALIBRATED
- 0-TO-250" H20.(USED TESTED).

- CAL
- 0-600 PSIG
- OUTPUT
- 4-20 MA
- MAX PRESS.
- 2000

- MAX. PRESS
- 300
- MAX PRESS
- 2000
- CAL
- 0-150 PSIG

- CAL
- 0-200 IN H20
- INPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- ROSEMOUNT SMART TRANSMITTER MODEL
- 1151DP4S25T0085D1
- CAL.
- 0-150 IN. H20.
- OUTPUT
- 4-20 MA

- ROSEMOUNT MODEL
- 300S1AAE5M5
- SUPPLY
- 10.5-42.4 VDC
- DATE
- 09/20

- FACTORY CAL
- TC K/2 WIRE/ 0-60 DEG F
- SUPLY
- 12.0-42.4 VDC OUTPUT 4-20 MA

- FACTORY CAL
- TC K/2 WIRE/0-160 DEG F
- SUPPLY
- 12.0-42.4 VDC OUTPUT 4-20 MA

- VEGA VAGA DIS 61 TYPE
- DIS61. INDICATOR FOR PLICS SENSORS XXKNB

- INNNPUT
- 0-100 VOLTS (0.3-0.6 KHZ)
- OUTPUT
- 0-20 MA DC

- INPUT
- 0-1.4 KHZ (100 VOLTS)
- OUTPUT
- 0-20 MA DC
- POWER
- 24 VOLT DC.

- OUTPUT POWER
- 10 WATTS
- FREQUENCY
- 400-520 MHZ
- VOLTAGE
- 7.4 V

- PART NO
- C20-DW-6 REV.A
- BAR CODE
- T82102951
- HERTZ
- 60

- FOXBORO PNEUMATIC PRESSURE TRANSMITTER MODEL
- 44BP
- TRANS OUTPUT
- 3-15 PSI.

- PART NO
- 13018329
- SD NO
- 105647
- DATE
- 2/22/17

- ROSEMOUNT TRANSMITER MODEL
- 2090FG2A2DE1M5E5
- CAL.
- 0-50 PSIG RTC
- SUPPLY
- 10.5-36 VDC

- MAX W.P.
- 750 PSI/ 52 BAR
- SUPPLY
- 10.5-55 VDC
- CAL
- 0 TO .5255IN H20

- CAL
- 0-250 IN H20
- TYPE
- DG
- RANGE
- 2

- CAL
- 0-600 PSIG
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- 0-260 PSIG
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- 0-1500 PSI
- OUTPUT
- 4-20 MA
- TYPE
- GP

- CAL
- 0-700 PSIG
- OUTPUT
- 4-20 MA
- TYPE
- DP/GP

- CAL
- 0-150 IN H20
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC

- CAL
- 0-150 IN H2O
- OUTPUT
- 4-20 MA
- SUPPLY
- 12-45 VDC MAX

- CAL
- 1-20
- SUPPLY
- 0-12.76 IN H20
- TYPE
- DP/GP

- CAL
- 0-10 IN H2O
- OUTPUT
- 4-20 MA
- SUPPLY
- 45

- CAL
- 0-25 IN WC
- TYPE
- DP/GP
- RANGE
- 3.

- CAL
- 0-2500 PSIG
- OUTPUT
- 420 MA
- TYPE
- GP

- CAL
- 0-1000 PSI
- OUTPUT
- 4-20 MA

- CAL
- 0-1000 PSI
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- 0-3000 PSIG
- TYPE
- GP
- RANGE
- 9

- ROSEMOUNT TRANSMITTER MODEL
- 1GP9E22M1B2
- TYPE
- GP
- RANGE
- 10

- CAL
- 0-2000 PSIG
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- 0-6000
- OUTPUT
- 4-20
- SUPPLY
- 12-45

- CAL
- 0-6000 PSI
- RANGE
- 5,10
- TYPE
- GP.

- CAL
- 0-300 PSI
- TYPE
- DP/GP
- RANGE
- 7

- CAL
- 1000-2000 PSIG
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- 0-100 PSI
- OUTPUT
- 10-50 MA
- SUPPLY
- 85 VDC MAX

- CAL
- 0-6 IN H20
- OUTPUT
- 4-20 MA
- TYPE
- DR

- CAL
- 0-2.5 IN H20
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- -1 TO 2 IN H20
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- -1.5 TO 0.5 IN H20
- INPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX.

- CAL
- -1 TO 1 IN H20
- OUTPUT
- 4-20 MA
- SUPPLY
- 45 VDC MAX

- CAL
- 0-3 IN WC
- OUTPUT
- 4-20 MA
- SUPPLY
- 45

- CAL
- 0-4 IN H20
- OUTPUT
- 4-20
- SUPPLY
- 45

- CAL
- 0 TO 50 PSID
- TYPE
- HP
- MAT'L
- 6

- CAL
- 15 TO 36 IN H20
- OUTPUT
- 4 TO 20 MA
- SUPPL
- 45 VDC MAX

- CAL
- 0-750 IN H20
- TYP
- HP
- MAT'L
- SST

- MAX W.P.
- 3626 PSI,/250 BAR
- CAL.
- 0 TO 1000 IN H2O
- INTEGRAL MANIFOLD MODEL
- 0305RC32B11B4

- MODEL NO
- 2013-0B
- SIZE
- 2"
- MAX CWP
- 285 PSI

- MODEL NO
- PL30A-1A1A W/GWD MIL
- CAPACITY
- 100-650
- PRESSURE RATING
- 150 PSI

- REV./G
- 2.30
- CAPACITY
- 100-650
- PRESSURE RATING
- 150

- MODEL NO
- PL30A-1A1A-0PW
- REV./G
- 2.30
- CAPACITY
- 60-650

- MODEL NO
- PL30A-1A1A-W/GWD MIL
- CAPACITY
- 100-650
- REV./G
- 2.30

- NO
- 751-001 20790504
- HERTZ
- 50/60
- INPUT
- 0.46 AMP

- BAR CODE
- 7008880040027
- HERTZ
- 50/60
- WATTS
- 1.2

- HERTZ
- 50/60
- VOLTS AC
- 120/240 VOLTS
- MPS
- 140

- BAR CODE
- 700880044506
- NO
- 16R0022717

- BAR CODE
- 700880043486
- NO
- 10631989

- M AMPS
- 1650
- CAPACITY
- 1500 MAH TO 1650 MAH (OEM STANDARD)
- CHEMISTRY
- LITHIUM-ION (LI-ION)

- FCC ID
- AZ489FT4826
- CAN TYPE
- WARUA1091955418A
- SUPER TANAPA
- PMUE1434ABN

- FCC ID
- AZ489FT4826
- CAN TYPE
- WARUA 109195418A
- SUPER TA NAPA
- PMUE1434BAN

- 6-BAY (6-BANK) MULTI-UNIT RAPID CHARGING STATION. MODEL
- HTN9005D
- INPUT
- 100-240 VAC
- AMPS
- 3

- NO
- A3127
- GP1280 HT SERIES
- HT750
- HT1550XLS. PRO SERIES
- PRO5150

- NO
- PMNN4069A 1217 AB4
- VOLTS
- 7.4
- WHATT H
- 10.4

- INDUSTRIAL DIN RAIL POWER SUPPLY. INPUT
- 200-500 VAC 4.0 AMPS
- HERTZ
- 50/60
- BAR CODE
- TC58048195

- VOLTAGE RANGE
- DC21.6 VOLT-26.4 VOLT

- CAT N O
- 800T-J2KC1B
- BAR CODE
- 10781180157834

- NO
- DG50T-21N 84447820
- RANGE
- 1-20 IN WC (2,5-50 MBR)
- TEMP
- -40/+140 DEG F (-40/+60 DEG C)

- S
- 20 MM NF
- UB
- 20…250 VOLTS AC/DC
- LE
- 350 MA AC/100 MA DC

- ANDERSON GREENWOOD INSTRUMENT MANIFOLD TYPE
- M4AVS
- ASSY.
- 02-2565-541
- 6000 PSI @ 200 DEG. F. 4000 PSI @ 500 DEG. F. BODY
- 316 SS

- ANDERSON GREENWOOD AGCO MOUNT ASSY
- 02.1639.545
- TYPE
- 3058382. (NEW)

- ROSEMOUNT INSTRUMENT MANIFOLD MODEL
- 0305RC22B11B4
- P/N
- C305111124-0000

- INC. PORTABLE DIGITAL PRESSURE GAUGE MODEL
- D1200
- MAX PRESSURE
- 6000 PSIG

- AMETEK MANSFIELD AND GREEN DIVISION DIGITAL TACHOMETER MODEL
- 1726

- EXTECH INSTRUMENTS HYGRO-THERMOMETER PLUS DEW POINT MODEL
- 4465CFA

- USG UNITED STATES GAUGES MODEL
- NO. 19010

- OVAL ENGINEERING CO. LTD. PULSE CHECKER MODEL
- PC-04
- INCLUDES AC ADAPTER MODEL
- 193,

- YOKOGAWA ELECTRIC CORP SLIDE RESISTER MODEL
- 2791
- 0.35 AMPS. S/N
- 58FR2153.

- YOKOGAWA ADMOG ELECTRIC CORP. MAGNETIC FLOW DETECTOR MODEL
- AM208DN
- SUFFIX
- AB1-LSA*A
- SIZE
- 80MM

- CHECK METER TYPE
- 6924-2000
- (4-20MA) 0-22 MA SHUNT 2.5 OHMS. S/N
- 6924GA013

- ENERGIZING INPUT
- 20 Ma DC
- INT. RESISTANCE
- 250 OHMS
- SUPPLY PRESSURE
- 10-100 PSI

- MPW
- 1000 PSIG
- Supply
- 24V DC
- Output
- 4-20mA DC

- FILL
- SIL
- M.W.P.
- 1500 PSIG
- SPAN ADJ.
- 25-150 IN H20

- ENCLOSURE
- PR-RPEIF-K
- STYLE
- A
- VOLT
- 120

- DENSITY D1
- 922754E-09
- DENSITY D2
- 769620
- FLUID TEMP
- -100 DEG. F TO + 450 DEG. F. WETTED PARTS CF3M/316L SST.

- FISHER & PORTER M/N
- 10A2227A

- ARMSTRONG STEAM TRAPS MODEL
- 1811 MAX FLOW 400 PSIG

- ARCHIVE CORPORATION
- CARTRIDGE TAPE DRIVE MODEL 5945S-1 S/N M658715

- CLASS 1 GROUPS B C D
- CLASS II

- FOXBORO MAGNETIC FLOW TRANSMITTER MODEL
- E96T-IA-A 120V 60HZ.

- ANDERSON GREENWOOD & CO. VALVE NO
- H1RDS2 02-1262-006

- INPUT
- 240VAC
- JUMPER 2-3 APPLY AC 1&4 FUSE
- 15A/250V

- MODEL NO
- DH11-004
- DIFFERENTIAL PRESSURE CONTROLLER SERIAL NO DATE CODE
- A16AB
- RANGE
- 0-1 IN W/C

- WITH P.I.C. MODEL
- W24B1
- DIPH
- TANT
- GASKET
- TFE

- DIAPH
- HASC
- GASKET
- 4401
- MWP
- 1480 PSIG @ 100 DEG. F.

- SFRIF GAUGE READING 0-100 PERCENT 4-20 MA SD8 447 146/2 S/N
- 0N51-0685.

- DIAPH
- 316L
- FIL
- SILICONE
- TYPE
- 20,