PANALYTICAL VENUS 200 MINILAB X-RAY SPECTROMETER MADE IN THE NETHERLANDS FOR ASTM D2622-98 AND ASTM D 4294

PANALYTICAL VENUS 200 MINILAB X-RAY SPECTROMETER MADE IN THE NETHERLANDS FOR ASTM D2622-98 AND ASTM D 4294

Location:Texas City, TX

Available quantity:1

Description

PANALYTICAL VENUS 200 MINILAB X-RAY SPECTROMETER MADE IN THE NETHERLANDS FOR ASTM D2622-98 AND ASTM D 4294 DY: 1173 MFG. MFG. DATE: 2006-11 60 HZ CE CSA LR 39487 C ZULASSUNG HE/RO/V/3 28/96. 4140/60 230 V~ 12NC 943004140601 1.1 KVA DY: 1173 SINGLE SAMPLE HOLDER. VENUS IS A COMPACT SEQUENTIAL X-RAY SPECTROMETER SYSTEM DESIGNED FOR THE ELEMENTAL ANALYSIS OF A WIDE RANGE OF SAMPLES. A SYSTEM CONSISTS OF A PW41X0/00 X-RAY SPECTROMETER COMBINED WITH THE DEDICATED VENUS ANALYTICAL SOFTWARE. THE PW41XX/00 VENUS 100 & 200 SPECTROMETERS HAVE BEEN DESIGNED FOR QUANTITATIVE AND QUALITATIVE ELEMENTAL ANALYSIS IN BOTH SCIENTIFIC AND INDUSTRIAL APPLICATIONS. THE PW41XX OFFERS A RANGE OF LOADING SAMPLE HANDLING AND OTHER OPTIONS; ENABLING EACH SPECTROMETER TO BE CLOSELY TAILORED TO THE USER REQUIREMENTS. THE INSTALLATION CONFORMS TO: INSTALLATION CATEGORY II AND POLLUTION DEGREE 2. FOR INDOOR USE. THE SPECTROMETER CAN BE FITTED WITH UP TO 12 CRYSTAL MEASURING CHANNELS AND ONE FIXED MEASURING CHANNEL AND A PARTIAL VACUUM SCANNER FOR MEASURING FROM SC TO U. NOTE: SOME CRYSTAL MEASURING CHANNELS REQUIRE 2 POSITIONS. THE PW41XX SPECTROMER CONSISTS OF TWO UNITS. THE LOWER CONSOLE CONTAINS THE WATER COOLING SYSTEM AND ACTS AS A TROLLEY ON WHICH THE UPPER UNIT IS MOUNTED. A (STEP-UP) TRANSFORMER IF REQUIRED CAN ALSO BE FITTED WITH THIS UNIT. THE UPPER SPECTROMETER UNIT CONTAINS ALL THE REMAINING SPECTROMETER ASSEMBLIES MEASURING CHANNEL SCANNING CHANNEL VACUUM SYSTEM MEASURING & CONTROL ELECTRONICS X-RAY TUBE HV POWER SUPPLY AND SAFETY & PROTECTION SYSTEMS. THE SPECTROMETERS ARE MICROPROCESSOR CONTROLLED.. THEY ARE OPERATED FROM AN EXTERNAL P.C. CONNECTED TO ONE OF THE TWO V24 (RS-232-C) INTERFACES ON THE REAR OF THE SPECTROMETER. THE COVER PANELS OF BOTH UNITS CAN BE REMOVED TO GIVE ACCESS FOR SERVICE AND REPAIR. FIGURE 1 SHOWS THE DIMENSIONS OF THE SPECTROMETER. THE CHOICE OF A SITE FOR THE SPECTROMETER WILL BE INFLUENCED BY LOCAL CONDITIONS SUCH AS EASY ACCESS FROM THE SAMPLE PREPARATION AREA AND THE PROCESS SAMPLING POINTS AVAILABILITY OF ELECTRICAL POWER ETC. LOGICAL PLANNING OF THE INSTALLATION CAN SAVE BOTH TIME AND MONEY. THE AIM OF THIS BOOKLET IS TO PROVIDE INFORMATION THAT WILL ENABLE THE BEST SITE TO BE CHOSEN AND TO ENSURE THAT THE REQUIRED SUPPLIES ARE AVAILABLE. NOTE: MEASUREMENTS ARE GIVEN IN METRIC UNITS. USEFUL CONVERSIONS ARE: PRESSURE: 1 MPA = 10(6) PA= 10ATM DEW POINT: THE TEMPERATURE AT WHICH CONDENSATION OR WATER VAPOR TAKES PLACE. TEMPERATURE: DEG. F. = 9/5 DEG. C. + 32. SPECTROMETER DIMENSIONS AND WEIGHTS EQUIPMENT IN CRATE: 1360 X 960 X 1000 MM WEIGHT: 307 KG UNCRATED ON PALLET: 1200 X 960 X 850 MM WEIGHT: 190-230 KG LOWER CABINET: 470 X 750 X 800 MM WEIGHT: 40 KG WEIGHT: 160-220 KG WEIGHT: DEPENDS ON TYPE GONIOMETER --- WEIGHT: --- ON THE REAR OF THE SPECTROMETER. B) THE WEIGHT IS DEPENDENT ON THE SPECTROMETER CONFIGURATION. I DID NOT CONNECT TO COOLANT GAS OR AIR WHEN OPENING THE PROGRAM INSTRUMENT HAS FOLLOWING ERRORS: 1). ERROR: SPECTROMETER INITIALIZATION ERROR 32,1,0,O: CRYSTAL TIMEOUT. 2). WARNING: SPECTROMETER WARNING 7,5,4,0: X-RAY TUBE IS OFF REASON BELOW 1 ERROR 3). WARNING SPECTROMETER WARNING 43,0,0,3047; CABINET TEMP TOO LOW 4) ERROR: SELECTED MOUNTING POSITION IS UNAVAILABLE FOR CHANNELS S-. EXIT ANGLES HAVE BEEN SET TO 40 DEG. FOR THESE CHANNELS

Specifications

ConditionUsed
PW4140/50 220 V~ 12 NC 943004140501 1.1 KVA
INCLUDINGCHAMBER
SPECTROMETER CABINET620 X 800 X 800 MM
WEIGHT120-160 KG
COMPLETE SPECTROMETER1090 X 800 X 800 MM
COMPUTERDEPENDS ON TYPE
NOTESA) THE DEPTH QUOTED FOR SPECTROMETER DOES NOT INCLUDE THE CONNECTIONS