PANALYTICAL VENUS 200 MINILAB X-RAY SPECTROMETER MADE IN THE NETHERLANDS FOR ASTM D2622-98 AND ASTM D 4294

PANALYTICAL VENUS 200 MINILAB X-RAY SPECTROMETER MADE IN THE NETHERLANDS FOR ASTM D2622-98 AND ASTM D 4294
Location:Texas City, TX
Available quantity:1
or
Call 409-761-0189
Description
PANALYTICAL VENUS 200 MINILAB X-RAY SPECTROMETER MADE IN THE NETHERLANDS FOR ASTM D2622-98 AND ASTM D 4294
DY: 1173 MFG. MFG. DATE: 2006-11
60 HZ
CE CSA LR 39487 C
ZULASSUNG HE/RO/V/3 28/96. 4140/60 230 V~ 12NC 943004140601 1.1 KVA DY: 1173 SINGLE SAMPLE HOLDER. VENUS IS A COMPACT SEQUENTIAL X-RAY SPECTROMETER SYSTEM
DESIGNED FOR THE ELEMENTAL ANALYSIS OF A WIDE RANGE OF SAMPLES. A SYSTEM CONSISTS OF A PW41X0/00 X-RAY SPECTROMETER COMBINED WITH THE DEDICATED VENUS ANALYTICAL SOFTWARE. THE PW41XX/00 VENUS 100 & 200 SPECTROMETERS HAVE BEEN DESIGNED FOR QUANTITATIVE AND QUALITATIVE ELEMENTAL ANALYSIS IN BOTH SCIENTIFIC AND INDUSTRIAL APPLICATIONS. THE PW41XX OFFERS A RANGE OF LOADING
SAMPLE HANDLING
AND OTHER OPTIONS; ENABLING EACH SPECTROMETER TO BE CLOSELY TAILORED TO THE USER REQUIREMENTS. THE INSTALLATION CONFORMS TO: INSTALLATION CATEGORY II AND POLLUTION DEGREE 2. FOR INDOOR USE. THE SPECTROMETER CAN BE FITTED WITH UP TO 12 CRYSTAL MEASURING CHANNELS AND ONE FIXED MEASURING CHANNEL AND A PARTIAL VACUUM SCANNER FOR MEASURING FROM SC TO U. NOTE: SOME CRYSTAL MEASURING CHANNELS REQUIRE 2 POSITIONS. THE PW41XX SPECTROMER CONSISTS OF TWO UNITS. THE LOWER CONSOLE CONTAINS THE WATER COOLING SYSTEM AND ACTS AS A TROLLEY ON WHICH THE UPPER UNIT IS MOUNTED. A (STEP-UP) TRANSFORMER
IF REQUIRED
CAN ALSO BE FITTED WITH THIS UNIT. THE UPPER
SPECTROMETER UNIT CONTAINS ALL THE REMAINING SPECTROMETER ASSEMBLIES
MEASURING CHANNEL
SCANNING CHANNEL
VACUUM SYSTEM
MEASURING & CONTROL ELECTRONICS
X-RAY TUBE
HV POWER SUPPLY AND SAFETY & PROTECTION SYSTEMS. THE SPECTROMETERS ARE MICROPROCESSOR CONTROLLED.. THEY ARE OPERATED FROM AN EXTERNAL P.C. CONNECTED TO ONE OF THE TWO V24 (RS-232-C) INTERFACES ON THE REAR OF THE SPECTROMETER. THE COVER PANELS OF BOTH UNITS CAN BE REMOVED TO GIVE ACCESS FOR SERVICE AND REPAIR. FIGURE 1 SHOWS THE DIMENSIONS OF THE SPECTROMETER. THE CHOICE OF A SITE FOR THE SPECTROMETER WILL BE INFLUENCED BY LOCAL CONDITIONS
SUCH AS EASY ACCESS FROM THE SAMPLE PREPARATION AREA AND THE PROCESS SAMPLING POINTS
AVAILABILITY OF ELECTRICAL POWER
ETC. LOGICAL PLANNING OF THE INSTALLATION CAN SAVE BOTH TIME AND MONEY. THE AIM OF THIS BOOKLET IS TO PROVIDE INFORMATION THAT WILL ENABLE THE BEST SITE TO BE CHOSEN AND TO ENSURE THAT THE REQUIRED SUPPLIES ARE AVAILABLE. NOTE: MEASUREMENTS ARE GIVEN IN METRIC UNITS. USEFUL CONVERSIONS ARE: PRESSURE: 1 MPA = 10(6) PA= 10ATM DEW POINT: THE TEMPERATURE AT WHICH CONDENSATION OR WATER VAPOR TAKES PLACE. TEMPERATURE: DEG. F. = 9/5 DEG. C. + 32. SPECTROMETER DIMENSIONS AND WEIGHTS EQUIPMENT IN CRATE: 1360 X 960 X 1000 MM WEIGHT: 307 KG
UNCRATED ON PALLET: 1200 X 960 X 850 MM WEIGHT: 190-230 KG
LOWER CABINET: 470 X 750 X 800 MM WEIGHT: 40 KG
WEIGHT: 160-220 KG
WEIGHT: DEPENDS ON TYPE
GONIOMETER ---
WEIGHT: ---
ON THE REAR OF THE SPECTROMETER. B) THE WEIGHT IS DEPENDENT ON THE SPECTROMETER CONFIGURATION. I DID NOT CONNECT TO COOLANT GAS OR AIR WHEN OPENING THE PROGRAM INSTRUMENT HAS FOLLOWING ERRORS: 1). ERROR: SPECTROMETER INITIALIZATION ERROR 32,1,0,O: CRYSTAL TIMEOUT. 2). WARNING: SPECTROMETER WARNING 7,5,4,0: X-RAY TUBE IS OFF
REASON BELOW 1 ERROR 3). WARNING SPECTROMETER WARNING 43,0,0,3047; CABINET TEMP TOO LOW 4) ERROR: SELECTED MOUNTING POSITION IS UNAVAILABLE FOR CHANNELS S-. EXIT ANGLES HAVE BEEN SET TO 40 DEG. FOR THESE CHANNELS
Specifications
| Condition | Used |
| PW | 4140/50 220 V~ 12 NC 943004140501 1.1 KVA |
| INCLUDING | CHAMBER |
| SPECTROMETER CABINET | 620 X 800 X 800 MM |
| WEIGHT | 120-160 KG |
| COMPLETE SPECTROMETER | 1090 X 800 X 800 MM |
| COMPUTER | DEPENDS ON TYPE |
| NOTES | A) THE DEPTH QUOTED FOR SPECTROMETER DOES NOT INCLUDE THE CONNECTIONS |