W.L. WALKER 18028CSU EXPLOSION PROOF HEATED ASTM OIL SWINGING BUCKET CENTRIFUGE 115 VOLT EXPLOSION PROOF 4-PLACE VARIABLE SPEED HEATED CENTRIFUGE FOR 100 ML SHORT CONE ASTM OIL TUBES. EACH MACHINE HAS FOUR PREHEATER POCKETS

W.L. WALKER 18028CSU EXPLOSION PROOF HEATED ASTM OIL SWINGING BUCKET CENTRIFUGE 115 VOLT EXPLOSION PROOF 4-PLACE VARIABLE SPEED HEATED CENTRIFUGE FOR 100 ML SHORT CONE ASTM OIL TUBES. EACH MACHINE HAS FOUR PREHEATER POCKETS
Location:Texas City, TX
Available quantity:1
or
Call 409-761-0189
Description
W.L. WALKER 18028CSU EXPLOSION PROOF HEATED ASTM OIL SWINGING BUCKET CENTRIFUGE 115 VOLT EXPLOSION PROOF 4-PLACE VARIABLE SPEED HEATED CENTRIFUGE FOR 100 ML SHORT CONE ASTM OIL TUBES. EACH MACHINE HAS FOUR PREHEATER POCKETS
18' WIDE
AND 10' HIGH; LIDS OPEN
23-1/2' WIDE
15-1/2' HIGH. NOT INCLUDING EXPLOSION PROOF FITTINGS THIS IS A FULLY AUTOMATIC BENCHTOP CENTRIFUGE DESIGNED FOR PETROLEUM TESTING. DETERMINING SEDIMENT AND WATER CONTENT IN CRUDE OIL
FUEL OILS
MIDDLE DISTILLATE FUELS
(STANDARD TEST METHOD FOR WATER AND SEDIMENT IN CRUDE OIL BY CENTRIFUGE METHOD. API 10.4 / ASTM D96
10.4 DETERMINATION OF WATER AND/OR SEDIMENT IN CRUDE OIL BY THE CENTRIFUGE METHOD (FIELD PROCEDURE). API MPMS CH. 10.6 / ASTM D1796 STANDARD TEST METHOD FOR WATER AND SEDIMENT IN FUEL OILS BY THE CENTRIFUGE METHOD. THIS CENTRIFUGE USES 100 ML SHORT TUBES. SHORT TUBES CAN BE USED FOR ASTM D4007
WHICH IS A LABORATORY PROCEDURE FOR DETERMINING THE AMOUNT OF WATER AND SEDIMENT IN CRUDE OILS OR FUELS. AS WELL AS ALL THE ABOVE METHODS. SERIAL NO: 609293-R
TEMP CODE T3C
CLI GP D
LR 88082-1
SA
C
US
POWER SWITCH: COOPER CROUSE-HINDS CONTROL ASSEMBLY COVER FOR HAZARDOUS LOCATIONS
AMPS: 20
702G LISTED
CL. I
GR. C.DCLII
GR. E,F,G CL.III
HEATER POWER SWITCH: CROUSE-HINDS CONTROL ASSEMBLY COVER FOR HAZARDOUS LOCATIONS
CAT NO: DS415
CL
I
GR
C,D
CL
II
GR
E,F,G
CL. III
M64
CHROMALOX PRECISION HEAT AND CONTROL: PART NO: 500515534
CAT NO: ARTM-750E2T5
280JM
VOLTS: 120
CLASS I DIV 1 GROUPS B,C & D
CLASS II DIV 1 GROUPS E,F(T3) & (GT3B)
CLASS III NEMA 3,4
CLASS I ZONE I EX D IIB
LINK MILTON ROY
LINC MODEL L 471-01-04
EXPLOSION PROOF
INDOOR/OUTDOOR
CLASS I
DIV. 1 GROUPS C,D
CLASS II
DIV. 1 GROUPS E,F,G
CLASS III DIV
I
0105471 REV.3
CL.I GR. CD CL.II GR. EFG. IT DOES APPEAR TO BE JUST AN ON/OFF SYSTEM. WHILE THE FACTORY DOCUMENTATION CLASSIFIES THE MOTOR SYSTEM AS VARIABLE SPEED TO MEET EXACT ASTM/API RCF REQUIREMENTS
THE SPEED VARIATION IS NOT CONTROLLED BY A USER-FACING DIAL INSTEAD
THE SPEED REGULATION IS HANDLED THROUGH TWO SPECIFIC INTERNAL MECHANISMS: INTERNAL DC CONTROLLER / RHEOSTAT: THE SPEED VARIATION IS ADJUSTED VIA AN INTERNAL MOTOR CONTROLLER BOARD OR RHEOSTAT TYPICALLY PRESET AT THE FACTORY TO STANDARD TESTING SPEEDS (E.G.
1600-1700 RPM). SOFT-START SWITCHING: THE UNIT UTILIZES AN INTERNAL SOFT-START SWITCH THAT AUTOMATICALLY CONTROLS THE RAMP-UP VARIATION SO THE MOTOR DOES NOT SHOCK THE SAMPLES UPON FLIPPING THE ON SWITCH. BECAUSE IT LACKS AN EXTERNAL POTENTIOMETER KNOB
IT FUNCTIONS OPERATIONALLY AS A FIXED-SPEED TOGGLE FOR THE END USER UNLESS OPENED FOR INTERNAL MECHANICAL ADJUSTMENT OR RECALIBRATION
Specifications
| Condition | Used |
| Serial Number | 3788212-7 |
| ONE IN EACH CORNER. CENTRIFUGE DIMENSIONS ARE | 18' DEEP |
| AND BIODIESEL. APPLICABLE TESTING STANDARDS | API 10.3 / ASTM D4007 |
| H.P. | ½ |
| POWER | 115 VOLTS |
| HERTZ | 50/60 |
| AMPS | 1.9 |
| CAT NO | DSD933 SA |
| VOLTS | 120 AC |
| TEMP CODE | T4 |
| KW | .75 |
| PH | 1 |
| TAG NO | 1809609 |
| OPTION | N |
| PSI | 1500 MAX |
| RELAY | D PDT |
| AMP | 10 |
| COIL | 120 VOLTS -40 DEG TO 400 DEG F |
| RELAY COVER | CROUSE-HINDS USA |