METTLER TOLEDO T50 TITRATOR INTERFACE: EQUIPPED WITH A HIGH-RESOLUTION, COLOR TOUCHSCREEN TERMINAL THAT FEATURES THE INTUITIVE ONE CLICK TITRATION USER INTERFACE.

METTLER TOLEDO T50 TITRATOR INTERFACE: EQUIPPED WITH A HIGH-RESOLUTION, COLOR TOUCHSCREEN TERMINAL THAT FEATURES THE INTUITIVE ONE CLICK TITRATION USER INTERFACE.

Location:Texas City, TX

Available quantity:1

Description

METTLER TOLEDO T50 TITRATOR METTLER TOLEDO TOUCH SCREEN 1 METTLER TOLEDO DMI 140-SC PROBE 1 METTLER TOLEDO COMPACT STIRRER 1 1000 ML WIDE MOUTH AMBER JAR 1 METTLER TOLEDO SWITCHING ADAPTER MAX WATTS: 46. METHODS: TYPE/ID/TITLE GT/M400/ACETIC ACID IN VINEGAR GT/M401/AMMONIUM CHLORIDE CONTENT GT/M402/FREE FATTY ACID CONTENT GT/M403/BLANK SOLVENT FFA GT/M404/CHLORIDE CONTENT IN KETCHUP GT/M405/TOTAL HARDNESS OF TAP WATER GT/M406/CA AND MG CONTENT OF TAP WATER GT/M407//SULFATE CONTENT GT/M408/BARIUM CONTENT CONDUCTOMETRIC GT/M409/COPPER CONTENT GT/M410/HYDROGEN PEROXIDE CONTENT GT/M411/VITAMIN C CONTENT VALTAMETRIC GT/M412/VITAMIN C CONTENT AMPEROMETRIC GT/M413/SDS CONTENT METRIC GT/M414/SDS CONTENT POTENTIOMETRIC GT/M415/M-VALUE OF TAP WATER (EP) GT/M416/P-VALUE OF TAP WATER (EP) GT/M417/ANTACID (STATING) GT/M418/HCI CONTENT (EP) GT/M419/FREE SO2 CONTENT IN WINE (EP) GT/M420/WATER CONTENT KF (EP) TITER/M421/TITER/KF (EP) GT/M422/DRIFT KF (EP) GT/M423/STANDBY KF (EP) GT/M424/BROMINE NUMBER ASTM D1159 (EP) GT/M425/BLANK ASTM D1159 (EP) GT/M426/ACID NUMBER ASTM D664 GT/M427/BLANK ASTM D664 (EP) GT/M428/BASE NUMBER ASTM 4739 GT/M429/BLANK ASTM D4739 GT/M430/BASE NUMBER ASTMD2896 GT/M431/BLANK ASTM D2896 GT/M432/CHLORIDE CONTENT IN MOTOR OIL GT/M433/MERCAPTAN SULFUR ASTM D3227 GT/M434/SDS CONTENT (2-PHASE) TITER/M435/TITER 0.1 MOL/L NAOH CALIB/M436/CALIBRATION DG111-SC GT/M437/HCI CONTENT CONDUCTOMETRIC GT/M449/ NITROGEN KJELDAHL WITH K-360 GT/M454/NITROGEN KJELDAHL TTL GT/M455/NITROGEN KJELDAHL MANUAL 24 VOLT 125 AMP 1. THE METTLER TOLEDO T50 IS A HIGHLY VERSATILE AUTOMATED POTENTIOMETRIC TITRATOR THAT SERVED AS THE ENTRY-LEVEL MODEL FOR THE MANUFACTURER'S PREMIER TITRATION EXCELLENCE LINE. WHILE THE T50 WAS OFFICIALLY DISCONTINUED BY METTLER TOLEDO IN FEBRUARY 2016 (SUCCEEDED BY THE MODERN T5 MODEL) IT REMAINS A ROBUST SOUGHT-AFTER WORKHORSE IN SECONDARY MARKETPLACES FOR INDUSTRIAL AND ANALYTICAL LABORATORIES. ? BURETTE CAPACITY: SUPPORTS 1 INTERNAL DRIVE AND IS EXPANDABLE UP TO 3 EXTERNAL DISPENSING DRIVES (MAX 50 ML CAPACITY). MEASUREMENT RANGE: DELIVERS HIGH-PRECISION DOSING DOWN TO A RESOLUTION OF 0.01 µL WITH A POTENTIAL RANGE OF ±2,000 MV. TITRATION TYPES: IDEAL FOR END POINT (EP) AND EQUIVALENCE POINT (EQP) TITRATIONS INCLUDING REDOX VOLTAMMETRIC COMPLEXOMETRIC NON-AQUEOUS METRIC AND PH-STAT MODES. KARL FISCHER INTEGRATION: FULLY CAPABLE OF RUNNING AUTOMATED VOLUMETRIC KARL FISCHER WATER DETERMINATION TESTS. COLOR TOUCHSCREEN TERMINAL THAT FEATURES THE INTUITIVE ONE CLICK TITRATION USER INTERFACE.

Specifications

ModelPSU50A-16-1
ConditionUsed
TYPETERMINAL
FNR51109017
SERIAL NO5131180610
SNR-DNR5131159941
10 ML BURET NO181401512
MODEL NOPSU50A-16-1
MWP50A16-S105
ORDER NOME-51109806
INPUT100-240 VAC
HERTZ50/60
AMPS1.6
OUTPUT5 VOLT
AMP1.5
POWER+5 VOLT 2.0 AMP
INTERFACEEQUIPPED WITH A HIGH-RESOLUTION