LAUDA WKL 1000 CIRCULATING CHILLER

LAUDA WKL 1000 CIRCULATING CHILLER
Location:Texas City, TX
Available quantity:1
or
Call 409-761-0189
Description
LAUDA WKL 1000 CIRCULATING CHILLER
POWER CONSUMPTION; 1,0 KW
DIN 12876-1
*=HFC/HFKW KYOTO PROTOCOL. WORKING TEMP RANGE: -10 TO 40°C | FILLING VOLUME: 8 TO 12L | ELECTRICAL: 115 V /60 HZ | AIR-COOLED DESIGN
MAX PUMP PRESSURE: 1.0 BAR | MAX PUMP FLOW: 30L/MIN | COOLING OUTPUT AT 20°C: 1.00 W | DIMENSIONS: 350 X 480 X 595 MM
LED DISPLAY AND 3-BUTTON OPERATION. FEATURES A SUBMERSIBLE PUMP THAT ELIMINATES SEAL PROBLEMS AT THE PUMP SHAFT. LAUDA RECIRCULATING CHILLERS PROVIDE A CONSTANT TEMPERATURE AND ALLOW CONSTANT FLOW OF LAB RESEARCH AND PRODUCTION IRRESPECTIVE OF THE TIME OF YEAR AND PRESSURE FLUCTUATIONS
DESIGNED FOR LABORATORY USE WITH ROTARY EVAPORATORS
SOXHLET EXTRACTORS
X-RAY UNITS
REFRACTOMETERS AND DISTILLING APPARATUS. THIS AIR-COOLED WKL 1000 CIRCULATION CHILLER WITH A FILLING VOLUME OF 8 TO 12 L HAS A CLOSED COOLER CIRCUIT FOR CONTINUOUS NONSTOP WORK IN RESEARCH PRODUCTION AT TEMPERATURES FROM -10 TO 40 °C. IT IS USED WHERE OPERATING HEAT HAS TO BE DISCHARGED RELIABLY AND QUICKLY IN CHEMICAL PRODUCTION PROCESSES OR FROM TECHNICAL SYSTEMS IN HARSH
CONSTANT USE ENVIRONMENTS. UNLIKE COOLING WITH TAP WATER
THIS CHILLING CIRCULATOR PROVIDES A CONSTANT TEMPERATURE IRRESPECTIVE OF THE TIME OF YEAR AND PRESSURE FLUCTUATIONS. THE INDEPENDENT COOLING-WATER SYSTEM INSTEAD OF A CENTRAL COOLING-WATER SUPPLY AVOIDS THE LEAKAGE OF SUBSTANCES THAT ARE HAZARDOUS TO THE ENVIRONMENT. THE WATER SAVINGS ALSO PROTECTS THE ENVIRONMENT AND SIGNIFICANTLY REDUCES OPERATING COSTS. THE WKL 1000 HAS AN LED DISPLAY AND A 3-BUTTON OPERATION
AND FEATURES A SUBMERSIBLE PUMP THAT ELIMINATES SEAL PROBLEMS AT THE PUMP SHAFT. STANDARD ACCESSORIES INCLUDE M16 X 1 PUMP CONNECTION THREADS
NIPPLES
AND SCREW CAPS. APPLICATIONS INCLUDE ROTARY EVAPORATORS AND SOXHLET SYSTEMS
ANALYTICAL DEVICES SUCH AS ELECTRON MICROSCOPES
X-RAY UNITS
REFRACTOMETERS
DISTILLING SYSTEMS
X-RAY CONTROL SYSTEMS SUCH AS AT AIRPORTS AND SEMICONDUCTOR SYSTEMS
CONTROL OF COOLING TRAPS SUCH AS IN THE DRYING OF GASSES
AND CENTRAL COOLING WATER SUPPLIES FOR COMPLETE LABORATORIES TO REPLACE COOLING WITH TAP WATER. WORKING TEMPERATURE RANGE: -10 TO 40 °C. RESOLUTION OF SETTING: 0.1 TO 1.0 °C. CONTROL: COMPRESSOR ON/OFF. TEMPERATURE STABILITY: +/- 0.5 K. EFFECTIVE COOLING OUTPUT AT 20 °C: 1.0 KW. EFFECTIVE COOLING OUTPUT AT 0 °C: 0.51 KW. EFFECTIVE COOLING OUTPUT AT -10 °C: 0.24 KW. PUMP CONNECTION THREAD: M16 X 1. NIPPLE DIAMETER: 10 MM. MAXIMUM PUMP PRESSURE: 1.0 BAR. MAXIMUM PUMP FLOW: 30 L/MIN. FOR TUBING: ½ IN. FILLING VOLUME: 8 TO 12 L. DIMENSIONS: 350 X 480 X 595 MM. PRESSURE MEASUREMENT/PARAMETER: NO. PROTECTION LEVEL: IP32. NOISE LEVEL: 50 DB (A). ADDITIONAL FEATURE: LEVEL INDICATION. POWER SUPPLY: 115 V/60 HZ. WEIGHT: 46 KG. LOADING: 1.1 KW. LAUDA #: LWG 473.
Specifications
| Condition | Used |
| TYPE | WKL 1000 |
| CATALOG NO | LWG 473 |
| SERIAL NO | LWG473-09-0007 |
| REFRIGERANT | R134A |
| FILLING CHARGE | 275 G |
| PS HIGH PRESSURE | 28 BAR |
| POWER | 115 VOLTS |
| HERTZ | 60 |
| PROTECTION CLASS | IP 32 |
| FUSE | T 115 AMP |