SIEMENS ENERGY & AUTOMATION INC. TYPE 1 ENCLOSURE 11-1129-03 REV.14

SIEMENS ENERGY & AUTOMATION INC. TYPE 1 ENCLOSURE 11-1129-03 REV.14

Location:Texas City, TX

Available quantity:1

Description

SIEMENS ENERGY & AUTOMATION INC. TYPE 1 ENCLOSURE 11-1129-03 REV.14 PANEL TYPE P1 SYSTEM 480Y/277 3 PH 4 250 AMPS MAX SEE MAIN DEVICE OR BREAKER PROVISIONS ARE FOR 100A MAX DEVICE TYPES BQD BQD BQD MINIMUM SIZE UL LISTED CABINET OR CUT - OUT BOX FOR THIS PANEL: 20"W X 5.75"DP X 44"H 15-A-1034-01 REV. 3 CATALOG NUMBER P1E42ML250CTS SALES ORDER NUMBER 79-50080 CUSTOMER MARKING HC ITEM NUMBER C00050 LOCATION D DATE 05/17/04 FIELD CONDUCTORS MAY BE SIZED FOR 60 75 DEG. C. CU OR AL UNLESS NOTED OTHEWISE ON THE DEVICE USE SIEMENS QF-3 FILLER PLATES TO COVER UNUSED 1" CIRCUIT SPACES FIELD INSTALLABLE KITS TO ADD MAINS AND TO CUSTOMIZE THE PANEL ARE LISTED ON THE REAR OF THE DEAD FRONT THE SHORT CIRCUIT RATING OF THIS PANEL BOARD IS 150,000 RMS SYMMETRICAL AMPERES AT 480 VOLTS MAX OR 22,000 RMS SYMMETRICAL AMPERESIF EQUIPPED WITH MAIN LUGS WITH FEED-THRU LUGS WITH NO PROTECTIVE DEVICE INSTALLED WHICHEVER IS LOWEST UNLESS A SERIES COMBINATION RATING IS UTILIZED ADDITIONAL OR REPLACEMENT BREAKERS SHALL BE OF THE SAME MANUFACTURE AND TYPES AS THOSE INSTALLED AND SHALL HAVE EQUAL OR GREATER SHORT CIRCUIT RATINGS IF SERIES COMBINATION RATINGS ARE UTILIZED SUITABLE FOR USE AS SERVICE EQUIPMENT ONLY WITH A MAIN OVERCURRENT DEVICE OR NOT MORE THAN SIX MAIN DISCONNECTING MEANS ARE PROVIDED AND WHEN NOT USED AS A LIGHTING AND APPLIANCE BRANCH CIRCUIT PANELBOARD;SEE ARTICLE 408.14 OF THE NEC IF MORE THAN 10% OF THE BREAKER POLES ARE SUPLYING LIGHTING ANS APPLIANCE CIRCUITS THEN THIS UNIT IS NOT TO EXCEED 42 CIRCUITS NEC ARTICLE 408.14 AND 408.15 BREAKER HANDLE IN THE INTERMEDIATE POSITION INDICATES TRIPPED TO RESET MOVE THE HANDLE TO THE EXTREME OFF POSITION THEN ON 15-A-1035-01 REV. 3 WITH 1. SIEMENS SENTRON SERIES CIRCUIT BREAKER CAT.NO. FXD63B200 SERIES C AMPS/A 200A VOLTS MAX 600V TYPE: FXD6A POLE: 3 CAL. BASE 40 DEG. C. CURRENT I NTERRUPTING RATINGS MAXIMUM RMS SYMMETRICAL 65KA 240V~ 50/60HZ 35KA 480V~ 50/60HZ 22KA 600V~ 50/60HZ LUG INFORMATION 60/75 DEG. C. AWG [MM2] TA1FD350A 6-1[13,3-42,4] CU/AI TORQUE LB.IN.[NM]120[13.6]1/0-350[53,4-177]CU/AI TORQUE LB.IN.[NM] 275[31.1] TC1FD350 6-1[13.3-42.2] CU120[13.6] 1/0-350[53.4-177] CU 275[31.1] CCF250 SEE INSTRUCTIONS SPECIAL PURPOSE NOT FOR GENERAL USE WHEN USED WITH TA6FD04 TA6FD04 14-4[2,0-21,1] CU 35[3,9] 6-4[13,3-21,1] AI 35[3,9] USE OUTER POLES FOR SINGLE PHASE NOM CSA LR13077 TIO CAAR HACR TYPE UL LISTED CIRCUIT BREAKER J-1361 E10648 PC.NO. 810419BK00 THIS DEVICE EQUIPPED WITH ACCESSORIES INDICATED BELOW SEE THE SIDE OF DEVICE FOR ELECTRICAL DATA LEFT POLE RIGHT POLE IEC 947-2 ~50/60HZ INTERRUPTING RATINGS VOLTS RMS SYMM U ICU ICS 220/240V~ 65KA 33KA 380/415V~ 35KA 18KA CE PC.NO. 810416F00 200A MAG. ADJ. 900-2000 1 LO 8 HI PC.NO. 71196A00 WITH 11. SIEMENS TYPE BQD CIRCUIT BREAKER 40 DEG. C. VOLTS MAX 480Y/277 VAC INTERRUPTING RATING MAX RMS SYMMETRICAL AMPS 65,000 A @ 240 VAC 14,000 A @ 480Y/277 VAC CU-AI 60/75 DEG. C. WIRE RATING 15-40A SIZE 14-10 LB.IN.35 SIZE 8 LB.IN.40 RATING 45-100A SIZE 6-4 LB.IN.45 SIZE 3-1/0 LB.IN.50 UL LISTED CIRCUIT BREAKER 3 POLE UNIT ISSUE NO. SA-9753 HACR CSA HID 800121GK00 WITH 9. SIEMENS TYPE BQD CIRCUIT BREAKER 40 DEG. C. VOLTS MAX 277 VAC 125 VDC INTERRUPTING RATING MAX RMS SYMMETRICAL AMPS 65,000 @ 120 VAC SWD 14,000 A @ 277 VAC HACR 14,000 A @ 125 VDC HID CU-AI 60/75 DEG. C. WIRE RATING 15-40A SIZE 14-10 LB.IN.35 SIZE 8 LB.IN.40 RATING 45-100A SIZE 6-4 LB.IN.45 SIZE 3-1/0 LB.IN.50 UL LISTED CIRCUIT BREAKER 1 POLE UNIT ISSUE NO. SA-3252 CSA 800121A19.

Specifications

ConditionUsed